New and Update IBM Redbooks

TS7650G and TS7650 ProtecTIER De-duplication Servers
Revised: August 7, 2009
http://w3.itso.ibm.com/redpieces/abstracts/sg247652.html?Open

Tuning System x Servers for Performance
Published: August 4, 2009 ISBN: 0738433071 848 pages
http://www.redbooks.ibm.com/abstracts/sg245287.html?Open

Implementing an iDataPlex Solution
Published: August 4, 2009 ISBN: 0738433233 272 pages
http://www.redbooks.ibm.com/abstracts/sg247629.html?Open

Managing Unified Storage with N-Series Operation Manager
Published: August 4, 2009 ISBN: 0738433160 576 pages
http://www.redbooks.ibm.com/abstracts/sg247734.html?Open



PowerVM Virtualization on System p: Intro & Configuration
Revised: July 29, 2009 ISBN: 0738485306 398 pages
http://www.redbooks.ibm.com/abstracts/sg247940.html?Open

Power 520 Technical Overview
Revised: July 29, 2009
http://www.redbooks.ibm.com/redpapers/abstracts/redp4403.html?Open

Brocade 8Gb FC Single-port and Dual-port HBA for System x
Published: July 31, 2009
http://www.redbooks.ibm.com/abstracts/tips0719.html?Open

QLogic 8Gb FC Single-port and Dual-port HBAs for System x
Published: July 31, 2009
http://www.redbooks.ibm.com/abstracts/tips0721.html?Open

System hang after update to 6100-03

Systems with Encypted File System (EFS) support enabled may fail to boot after updating to the 6100-03 Technology Level.

This problem occurs if the clic.rte.kernext and clic.rte.lib filesets are installed at a
level below 4.6.0.0. EFS may be enabled if the 'efsenable' command was ever executed
on the system, even if there are no encrypted file systems currently in use. The presence of the file /var/efs/efsenabled indicates that EFS is enabled.
To avoid this issue, update the clic.rte.kernext and clic.rte.lib filesets to the 4.6.0.0 level from the clic.rte image available on the AIX Expansion Pack, dated 5/2009 or later. The clic.rte filesets need to be updated before the system is rebooted after updating to the 6100-03 Technology Level.

If the 6100-03 Technology Level is installed without updating the clic.rte filesets to the 4.6.0.0 level, the system may fail to reboot. Should this occur, you can recover using the following procedure.

1. Reboot system into service mode
2. Select 'Task Selection', then chose 'Shell Prompt'
3. Move file /var/efs/efsenabled to /var/efs/efsenabled.SAVE
4. Reboot system into normal mode
5. Update clic.rte.kernext and clic.rte.lib to the 4.6.0.0 level
6. Move back /var/efs/efsenabled from /var/efs/efsenabled.SAVE

Distribution of the 6100-03 Technology Level on Fix Central has been temporarily suspended until this issue is resolved.

So, be warned!